IECC
Table 802.2(2) 
This proposal eliminates the distinction between "factory
assembled" and "site built" fenestration products, adjusts
the U-factor for commercial glazed systems to a reasonable
level that manufacturers of commercial glazed systems can
meet while still providing systems that have the strength
and durability needed in commercial buildings and revises
the SHGC requirement for residential type windows to be consistent
with the requirements for residential windows in Chapter 4
of the IECC and Chapter 11 of the IRC.
IECC
Section 402.5.1 
402.5.1 Maximum fenestration U-factor and SHGC. The area weighted
average maximum fenestration U-factor permitted using trade
offs from Section 402.1.3 or Section 404 in zones 4 through
8 shall be 0.48 for vertical fenestration and 0.75 for skylights.
The area weighted average maximum fenestration SHGC permitted
using trade-offs from section 404 in zones 1 through 3 shall
be 0.50. |